You searched for "intraocular "

885 results found

Under pressure: the constant drive to improve IOP monitoring

The authors offer a comprehensive overview of interplay between glaucoma and intraocular pressure (IOP), IOP measurement principles and historical measurement techniques and progress in IOP measurement devices. The authors explore the issues surrounding current thinking in IOP measurement and its...

DIY IOP – does it work?

Measuring intraocular pressure (IOP) plays a major role in glaucoma care as IOP is a parameter, along with visual field progression and optic disc cupping used to assess treatment effect. While Goldmann tonometry (GAT) is the gold standard, it only...

Outcomes of cataract surgery in eyes with weak zonules

Pseudoexfoliation (PEX) and zonular weakness have long been known to increase the risk of complication of cataract surgery. This retrospective study looks at the results of phacoemulsion and intraocular implantation in 295 eyes with pseudoexfoliation and zonular weakness, with a...

Predictors of IOP reduction after SLT

The aim of this study was to identify predictors of intraocular pressure reduction following selective laser trabeculoplasty (SLT) in patients with primary open-angle glaucoma, who are already taking maximally tolerated IOP-lowering medication and need further IOP reduction. In this prospective...

IOL cataract surgery in seven to 24 month olds

The purpose of this study was to present the long-term outcome of IOLs in paediatric patients who received cataract surgery aged seven to <24 months. This was retrospective study with minimum follow-up of 12 months for 27 patients (28 eyes)....

Cataract surgery and circadian photoentrainment

The study authors sought to investigate the possible effects of circadian photoentrainment following cataract. This was a randomised clinical trial, where 76 eyes of 76 patients (with bilateral cataract) were randomised to blue-blocking or neutral intraocular lenses (IOLs). Outcome measures...

IOL cataract surgery 7-24 months

The purpose of this study was to present the long-term outcome of IOLs in paediatric patients who received cataract surgery aged seven to <24 months. This was retrospective study with minimum follow-up of 12 months for 27 patients (28 eyes)....

Pentacam vs. IOL Master keratometry measurement in IOL power calculations

The IOL Master measures only the anterior corneal curvature and estimates the total corneal power by assuming a fixed relationship between the anterior and posterior corneal surface. The Pentacam measures both the anterior and posterior corneal surface and therefore calculates...

High myopes with POAG and IOP fluctuations

The authors describe a prospective study of 80 eyes of Chinese patients with primary open-angle glaucoma (POAG) on prostaglandin analogues to investigate if those who also have high myopia exhibit greater short-term intraocular pressure (IOP) fluctuations at resting conditions over...

Two bifocals and a trifocal

The authors compare the optical outcomes of two bifocal intraocular lenses (AcrySof ReSTOR +2.50 Diopter [D] add +3.0D add) with a trifocal lens (AT LISA tri 839MP). The optical qualities of the lenses were quantified by measuring the modulation transfer...

Rotational stability of angle supported phakic IOL

The authors evaluate 50 eyes of 28 patients that underwent an angle fixated phakic intraocular lens (IOL) implantation (Acrysof Cachet). All eyes had moderate to high myopia (-5.25 to-19.63 dioptres) and IOL sizing was performed as per the manufacturer’s recommendation....

Effect of phacoemulsification on facility of outflow

This is a prospective study to examine the change in electronic Schotz tonographic outflow (TOF) and IOP measurements after phacoemulsification. Intraocular pressure was measured using Goldman‘s applanation tonography (GAT). Data were collected at baseline, three, six and 12 months postoperatively....