You searched for "orbital"

2274 results found

Manchester Royal Eye Hospital first in UK to use ultra-wide field OCT angiography machine in patient facing setting

Manchester Royal Eye Hospital announces it is the first in the UK to utilise the ultra-wide field OCT angiography machine, the Xephilio OCT-S1 from Canon, in a patient facing setting.

Dr William Mackenzie: a founding figure of modern ophthalmology

The author looks at the career of William Mackenzie and the important role he played in establishing the status of ophthalmology as a recognised medical speciality. There are certain individuals who, blessed with ability and means, are destined to leave...

The ABC tragedies: Part one

“In the midst of tragedy, we start the comedy” – Agatha Christie, The ABC Murders. Throughout a career in medicine, we are often faced with tragedy. One of the coping mechanisms is to use humour to navigate the mini everyday...

Haag-Streit offers free downloadable breath shield template

Haag-Streit has offered users a free downloadable breath shield template for its slit lamps.

DVLA publishes revised list of notifiable conditions list for drivers following AOP advice

The AOP have been actively working with the DVLA since serious concerns were raised over its extended list of notifiable conditions at the end of last year.

Supranuclear palsy

This paper reports the results of surgery for supranuclear monocular elevation deficiency. Contralateral superior rectus maximal recession was undertaken without interfering with the superior oblique tendon position, transection of the superior oblique to the superior rectus frenulum and directly suturing...

Automated Bruckner device accuracy

The authors developed a Bruckner device, examined volunteers and determined the relation between the luminance of the red fundus reflex and eye rotation. Eye rotation was varied continuously both horizontally (-7 to 8 degrees) and vertically (five degree total range)...

Lester Jones tubes: Can these be tolerated long-term?

The authors present a retrospective case review study of a cohort of patients with Lester Jones’ tubes first placed between 1969 and 1989, and who were reviewed within the last 15 years. Twenty-nine patients (33 eyes) were included in the...

Resection versus advancement for consecutive XT

The authors performed a retrospective review of results for patients treated with resection for consecutive exotropia in comparison to patients treated with advancement to the original insertion. The age of the resection and advancement groups averaged 33.6 and 38.2 years...

Effects of topical anaesthetic on intraocular pressure

This prospective interventional study assessed the effects of repeated intraocular pressure (IOP) using Goldmann applanation tonometry and applanation resonance tonometry in six volunteers. Previous literature supports IOP reduction using repeated applanation tonometry. Repeated IOP measures were taken alternately on 12...

High-fluence collagen cross-linking

The authors treat seven eyes with progressive keratoconus with a high energy (18mW) for five minutes delivering a total energy similar to that suggested by the original Dresden protocol (3mW for 30mins). All eyes had a thickness >400µm following epithelial...

Augmented surgery for monocular elevation deficiency

The outcomes are described for augmented lateral rectus superior transposition in cases of acquired monocular elevation deficiency (MED) associated with large hypotropia in primary gaze. The lateral rectus was transposed superiorly and reinserted on sclera between the temporal margin of...