You searched for "sclera"

220 results found

Visual outcomes after surgery for primary RRD in era of microincision vitrectomy

This is a prospective, multicentre, nationwide study between 2016 and 2017, to investigate the preoperative ocular factors, surgical techniques (pars plana vitrectomy (PPV) or scleral buckling (SB), or combined procedures) for rhegmatogenous retinal detachment (RRD) and postoperative best corrected visual...

Long-standing flattening effects on the globe following spaceflight

Posterior globe flattening has been well-documented in astronauts both during and after long-duration spaceflight (LDSF). This globe flattening is thought to be due to the disc centred anterior forces created by elevated volume and / or pressure within the optic...

IOL power calculation accuracy in childhood cataract surgery

Refractive outcomes in eyes after vitrectomy vary as the timing of cataract surgery may influence the outcome when done as staged surgery after vitreoretinal (VR) surgery or at the same time as VR surgery. The authors aimed to determine the...

Cystoid macular oedema following retinal detachment surgery

There are limited studies examining the incidence and risk factors for postoperative cystoid macular oedema (CMO) following rhegmatogenous retinal detachment (RRD) repair. Postoperative CMO is thought to be due to pro-inflammatory state, where numerous cytokines lead to tight junction dysfunction,...

Outcomes from evisceration with primary implant in 1800 patients

This is a retrospective analysis of 1800 patients who had evisceration with orbital implant between 2013-2019. As the largest published series on this topic, the authors are able to give relatable real-world data on complications following surgery. They use a...

In conversation with Andrena McElvanney (President, MCLOSA)

We spoke to Andrena about MCLOSA's annual meeting this November, key developments in cornea and external eye disease, and plans for the association’s 30th anniversary. Andrena McElvanney (top, second from right) and the OSI council members. The Medical Contact Lens...

Ocular bubbly: a vitreoretinal update on the art of gases

The authors remind us of the revolutionary impact gases have had on retinal surgery. In 1938, Rosengren attempted to improve his retina repair surgical outcomes [1]. He discovered that suturing the retina or pressing externally on the sclera were not...

My message to future ophthalmology teaching fellows: Organising an effective ophthalmology placement

Globally, teaching ophthalmology during the undergraduate period presents challenges. The time allocated for it is minimal with substandard exposure [1,2]. Additionally, the number of universities mandating formal ophthalmology education has significantly declined [3]. Research supports the observation that doctors in...

Myopia management

With the growing prevalence of myopia at epidemic levels in some countries and increasing number of research publications on myopia control, there is a lot of controversy regarding the management of myopia. As none of them are at present available...

Suture-less flanged IOL fixation vs. conventional sutured SF in IOL dislocation

The authors report the analysis of a prospective, comparative cohort study on 103 consecutive patients (103 eyes) with intraocular lens (IOL) dislocation who underwent vitrectomy with IOL removal and sutured scleral fixation (SF) (53 eyes) or flanged IOL fixation (50...

Haag-Streit launches Eyesi Indirect Ophthalmoscope ROP simulator for retinal examinations on preterm infants

The Eyesi Indirect ROP is a mixed-reality simulator that offers a highly immersive training environment for proper device handling, with an embedded, didactically structured simulator curriculum to teach the diagnostic skills required for correct ROP classification.

First UK Direct Selective Laser Trabeculoplasty (DSLT) device placed at Moorfields

Following an internationally successful Randomised Controlled Trial (RCT) comparing the Direct Selective Laser Trabeculoplasty (DSLT) with standard SLT, the first ever commercial device in the UK, the ‘Eagle’, has been installed and is in use at Moorfields Eye Hospital in London.