You searched for "Pentacam"
Corneal Topography in Clinical Practice (Pentacam System)
This book is based upon one device, the Pentacam, developed by OCULUS, and is primarily aimed at those who wish to familiarise themselves with the Pentacam system and need a text to complement the instrument operations manual. It is laid...Pentacam vs. IOL Master keratometry measurement in IOL power calculations
1 June 2014
| Anjali Gupta
|
EYE - General
The IOL Master measures only the anterior corneal curvature and estimates the total corneal power by assuming a fixed relationship between the anterior and posterior corneal surface. The Pentacam measures both the anterior and posterior corneal surface and therefore calculates...
OCULUS Pentacam® OCT
The OCULUS Pentacam® Cornea OCT offers 360° 3D imaging by combining Scheimpflug and Cornea OCT technologies. It delivers consistent 1.9μm resolution across the entire cornea, with validated Scheimpflug data and OCT imaging. The system integrates seamlessly with the existing Pentacam®...Diagnostic accuracy of different keratoconus detection indices of pentacam in paediatric eyes
This is a retrospective study of 432 non-keratoconic eyes compared with 48 eyes with keratoconus (KC) or forme fruste KC (FFKC) in a paediatric population in Cairo, Egypt between December 2013 and October 2018. The authors discuss the rationale of...Birmingham Optical @ 100% Ophthalmology: Surfing the Pentacam AXL wave
24 February 2024
@10:30 – 11:30
Evaluation of keratometry with a novel colour LED corneal topographer
The Cassini topographer (i-Optics), which analyses corneal shape based on the reconstruction of specular reflections on 679 coloured LEDs, generates keratometry and is the new machine being compared in this study with other keratometry devices. The prospective comparative study included...Corneal and astigmatic changes after medial rectus recession surgery of 6mm
This study prospectively compared changes in astigmatism before and two months after unilateral recession of medial rectus muscles using Pentacam. The fellow unoperated eye was used as the control eye. The study included 66 eyes and 33 patients; 21 males,...Keratoconus cone variants
This retrospective study examined correlation between three keratoconic parameters to further understand anatomy of keratoconic cones. Kmax and pachymetry of the thinnest point were obtained from the Pentacam scans. Decentration was calculated as distance from the corneal vertex to the...Scheimpflug vs. OCT in measuring corneal thickness
The authors report on the reproducibility and repeatability of corneal thickness measurements using three different Scheimpflug imaging cameras (Pentacam, Sirius and Galilei) and one Fourier-domain optical coherence tomography (OCT) system (RTvue-100). The rationale for this study is that corneal thickness...BESTi: a new index to detect subclinical keratoconus
In this multicentre, case-control study, the authors develop a new index, named Boosted Ectasia Susceptibility Tomography Index (BESTi), to detect early cases of keratoconus. This index was derived from multiple logistic regression analysis of 22 variables of tomography scans. The...Long-term results of cross-linking treatment for keratoconus
The authors report on the long-term outcomes in a prospective case series of patients with keratoconus undergoing corneal collagen cross-linking (CXL) treatment. Thirty-two patients (40 eyes; mean age 22.5+/-5.5 years) with Grade I, II and III progressive keratoconus were recruited...Dramatic myopic shift due to epithelial basement membrane dystrophy
3 October 2024
| Annes Ahmeidat, Blazej Staniszewski, James Welch
|
EYE - Cornea
Epithelial basement membrane dystrophy (EBMD), also known as map-dot-fingerprint dystrophy, is a common anterior corneal disorder affecting approximately 2% of the population [1]. It is characterised by the abnormal maintenance of the basement membrane, resulting in protrusions into the epithelium....